How should I perform leak detection on my vacuum furnace?
2024-02-21 08:45:28

Question 1: How should I perform leak detection on my vacuum furnace?

The leakage detection of vacuum furnaces mainly adopts two methods: spraying method and suction nozzle method. Spray method is a traditional leak detection method, as shown in Figure 1. It is to vacuum the furnace and apply helium gas outside the furnace (such as connecting a helium mass spectrometer), and then observe the results.

Another method is the nozzle detection method, which is suitable for situations where your test object cannot be evacuated. When using this method, you need to charge a leak gas (such as helium) into the object being tested. Examples of tested objects include heat exchangers, water-cooled flanges, water-cooled fans and shafts, electric feeders, water jackets, etc. After the tested object is filled with leakage gas, use a sensor to check whether there is any external gas leakage. Helium mass spectrometer can also be used for this detection method.

Leakage detection of inert gases is also important. This is because the leakage rate of the entire recharge system - from the liquid gas storage system to the vacuum furnace - must be zero. If inert gas leaks out from the gas supply system or the gas valve on the furnace body, it will cause the vacuum furnace to show signs of poor pumping effect, poor sealing, poor ultimate vacuum degree, difficulty in discharging normal gas release, backflow, and other errors.

There are also two commonly used detection methods for inert gas leakage, namely thin film (soap bubble) leak detection and vacuum leak detection. Generally speaking, the thin film leak detection method is the easiest and fastest high-pressure inert gas leak detection method. It sprays a certain leak indicator liquid in a known suspicious area, and if bubbles are generated in any inspection area, you can know that a leak has been detected.

Vacuum leak detection is a more accurate method. It separates the liquid nitrogen or liquid argon storage system from the vacuum furnace, ensuring that the entire system is in a vacuum state, and then uses a helium mass spectrometer to check for leaks in the system. When conducting vacuum leak testing, you should:

1. Close the external gas valve to disconnect the external liquid gas system from the evaporator, recharge storage tank, vacuum furnace, and all supporting pressure reducing and recharge pipelines.

2. Use the normal suction system of the vacuum furnace to vacuum the furnace.

3. Perform pressure reduction operation on the recharge tank.

4. Manually power on the recharge valve on the furnace body to open it. This operation should be carried out by experienced experts in accordance with safety regulations.

Once you open the recharge valve and depressurize the recharge tank to atmospheric pressure, the vacuum furnace begins to remove gas from the pipeline. From the gas storage tank and evaporator to the closed external gas valve, the gas inside will be extracted. Then, you can use the vacuum furnace's exhaust system to exhaust the entire recharge system, making the entire system reach a vacuum state. Next, you should use a helium mass spectrometer to perform leak detection on the system.

After completing all leak tests for the vacuum furnace and inert gas, you must eliminate each leak one by one.


Related tags:

Comment

(0)
*Captcha:
Contact Information
Jinzhou TongHui Vacuum Metallurgical Technology Co., Ltd.

Add: No. 461-1, Maoshan Village, Zhongtun Township, 

Guta District, Jinzhou City, Liaoning Province


Tel: +86-15084179090

E-mail: 1045072944@qq.com

Website: en.jzthzk.cn


FOLLOW US

Copyright  ©  2024 Jinzhou TongHui Vacuum Metallurgical Technology Co., Ltd.