Latest News
Home > News Center > Company News

Common vacuum measurement methods for vacuum furnaces
2024-02-21 08:45:43

1、 Compression vacuum gauge

A compression vacuum gauge is connected to a capillary tube with a closed top, and the lower end is connected to a port of a Y-shaped tube. A mercury storage device is connected below the Y-shaped tube. When in use, connect the vacuum system to the Y-shaped tube port, rotate the vacuum gauge to compress mercury gas, and then turn it to a vertical position to read the liquid level difference between the "measuring capillary tube" and the "comparing capillary tube", which is the measured vacuum degree. The advantage of a compressed vacuum gauge is its high measurement accuracy, which can be used as a standard for vacuum measurement. His shortcomings are not convenient to use, slow response, and inability to measure continuously. Due to the fact that compression vacuum gauges are made based on gas laws, they can only measure permanent gas partial pressure and cannot measure vapor pressure. In vacuum systems with high steam partial pressure, the reading of a compression vacuum gauge cannot indicate its vacuum degree.

2、 Thermal conductivity vacuum gauge

Two types of thermal conductivity vacuum gauges, namely resistance vacuum gauge and thermocouple vacuum gauge, are made based on the principle that the number of molecules in the vacuum system is related to the conduction heat. When passing through an electric current, the temperature rises, the periodic gas is heated, and the temperature of the regulating tube wall is low. By relying on the surrounding gas molecules to conduct heat, the temperature change of the resistance wire reflects the amount of gas molecules present. It is inconvenient to directly measure the temperature of the resistance wire. As the resistance value of the resistance wire is related to temperature, a bridge can be used to measure its resistance value. The advantages of a thermal conductivity vacuum gauge are: 1. It can measure the total pressure; 2. Can continuously measure; 3. Easy to use, can be measured remotely using wires; 4. Simple structure, easy to manufacture; Its disadvantages are: 1. There is thermal inertia, and when the pressure changes quickly, the reaction lags behind; 2. The external temperature has a certain impact on the measurement results; 3. Changes in the surface condition of the resistance wire can cause zero drift and affect accurate readings.

3、 Ionization vacuum gauge

It is based on the ionization phenomenon of gases to measure the degree of vacuum, and can be divided into two types: hot cathode ionization vacuum gauge and magnetron discharge vacuum gauge. When a certain power supply is applied to each pole, the filament is in an incandescent state, emitting hot electrons. These electrons collide with gas molecules inside the tube, causing the gas to ionize and producing whole ions. Ions are collected as ions, forming an electric current, which also changes with the change of pressure. By measuring the magnitude of the current, a vacuum can be measured. The advantages of a hot cathode ionization vacuum gauge are: 1. It can measure the total pressure; 2. Can be continuously measured; 3. Wide measurement range and high sensitivity; 4. The ionization gauge has a small volume and can be directly connected to the location to be measured; 5. Not sensitive to mechanical vibration, with low inertia; 6. The calibration curve is linear; Its disadvantages are: 1. The reading is related to the type of gas, and different gases require different curves to be made; 2. The filament is in an incandescent state, and sudden air leakage or pressure increase in the vacuum system can cause damage to the filament; 3. Gas is adsorbed on the cathode and collection surface, which can easily cause measurement errors; 4. At low voltage, the discharge phenomenon between the regulating shell and the electrode affects the reading;

The magnetron discharge vacuum gauge also utilizes the principle of gas discharge, but there is no hot cathode in the regulation. There are two parallel cathodes in the regulation, and there is a frame shaped electrode in the middle of the two parallel plates. The electrode part of the entire regulation is in a magnetic field. Due to the effect of an external magnetic field and the frame shape of the anode, it is easy for electrons to cross, causing them to undergo multiple spiral movements back and forth in space. By increasing the ionization effect, the sensitivity of the vacuum gauge also increases. Its advantages are: 1. There is no hot cathode present, which will not damage the filament due to air leakage; 2. Measure the total pressure continuously; 3. The discharge current is high, and the circuit is simple to use with instruments; 4. The structure is sturdy and insensitive to the outside world; Its disadvantage is that under pressure conditions, its sensitivity is not as high as that of a hot cathode ionization vacuum gauge, and different calibration curves are required for different gases;

Related tags:

Comment

(0)
*Captcha:
Contact Information
Jinzhou TongHui Vacuum Metallurgical Technology Co., Ltd.

Add: No. 461-1, Maoshan Village, Zhongtun Township, 

Guta District, Jinzhou City, Liaoning Province


Tel: +86-15084179090

E-mail: 1045072944@qq.com

Website: en.jzthzk.cn


FOLLOW US

Copyright  ©  2024 Jinzhou TongHui Vacuum Metallurgical Technology Co., Ltd.